Natural Gas Liquids (NGL)—from LPG to propylene—require high-integrity pipelines backed by high-integrity inspection data.
Dexon’s UT-MC Falcon tool delivers just that: high-resolution metal loss and geometry data designed for NGL pipelines.
Detection Specs:
Metal Loss POD (90%)
• Depth: ≥1.0 mm
• Length & width: ≥5×5 mm
Metal Loss POS
• Depth sizing: ±0.3 mm
• Length & width sizing: ±6 mm
Real-World Testing & Real-World Trust
• 7-acre Test Yard with Infinity Loop: Simulates real conditions before a single meter is run
• Verifiable Testing: Confirm POD, POS, and POI pre-mobilization
• Reliable Execution: 93% first-run success; 97% on-time final reports
• Customized Solutions: Tools tailored for unpiggable pipelines
• Proven Partner: 29 years in business with some of the world's largest energy companies
Dexon does not do guesswork—we do verified, high-resolution inspections that give full visibility into a pipeline.